Measure the total run out (RUO)
The concentricity and the axial run-out are part of the group of so called running tolerances. The tolerated elements of the axial run-out tolerance are perimeter line or circular line. The tolerated elements of the total running tolerance are circumferential surface and end surface.
Concentric tolerance
The tolerance zone is limited in the measuring plane vertical to the axis by two concentric circles at distance t, the common centre of which is on the reference axis.
Total concentric tolerance
The tolerance zone is limited by two coaxial cylinders at distance t, which are parallel to the reference axis.
Axial run-out tolerance
The tolerance zone is limited by two parallel levels at distance t, vertical to the reference axis.
Total run-out tolerance
The tolerance zone is limited by two parallel levels at distance t, which is vertical to the reference axis.